Migration of Soluble Polymers in Human Saliva during Swabbing Characterized by Direct Electrospray Ionization Mass
Qiaoyun Huang1, Jianfeng Zhang1, Songbin Dong1
1College of Environment and Climate, Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, and Guangdong Provincial Key Laboratory of Speed Capability, Jinan University, Guangzhou 510632, China.
Abstract:
Medical swabs are commonly used in routine medical sampling and testing of human body fluids, such as saliva and sputum. Many medical swabs are made of plastic polymers. Exposure to plastic medical swabs containing many free soluble polymers and residual monomers could increase the potential health risk. Conventional analytical methods for assessing personal exposure to polymers usually require complex sample preparation and time-consuming analytical procedures. In this study, we established a direct electrospray ionization mass spectrometry method to investigate the occurrence and species of soluble polymers in different medical swabs. The migration of typical soluble polymers, i.e., PA6 and PEG, was found in medical swabs and human saliva after swabbing within seconds. The amounts of PA6 and PEG were found to be nanograms per swab. Trace polymer could rapidly reside in saliva within seconds (e.g., 3 s). The exposure level of polymer residual was evaluated during different swabbing times and saliva volumes, showing the concentration of soluble polymers in saliva at the ng/mL level. Despite the low concentration and low toxicity of soluble polymers in saliva, it is anticipated that this method could offer a convenient and simple way to evaluate polymer exposures rapidly. We also hope our findings will attract more attention to the health risks of ubiquitous plastic materials in daily life and propose an efficient strategy to eliminate saliva polymers.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...