Related Experiment Video
Updated: May 21, 2025

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
The Influence of Height on Occupational Radiation Exposure of Interventional Cardiologists During Selective Coronary
Richard Casazza1, Bilal Malik1, Arsalan Hashmi1
1Department of Cardiology, Maimonides Medical Center, Brooklyn, New York.
Abstract:
Radiation exposure is one of the most adverse occupational hazards faced by interventional cardiologists. Operator height can influence operator radiation exposure. This single-center retrospective study (n = 534) assessed the cumulative radiation (CR) exposure in μSv and normalized radiation exposure (CR/DAP) using three different ranges of height (short, regular, and tall) of the primary operator at four anatomical locations when using a radial artery approach. A multivariate linear regression analyses for cumulative operator radiation dose found that tall operator height had significantly lesser values than regular operator height for the thorax (p <0.001), abdomen (p = 0.01), left eye (p <0.001), and right eye (p <0.001). Short operator height did not significantly differ from regular operator height. Multivariate linear regression analyses for normalized operator radiation dose found that tall operator height had significantly lesser values than regular operator height for the thorax (p <0.001), abdomen (p = 0.01), left eye (p <0.001), and right eye (p = 0.002). Short operator height did not significantly differ from regular operator height. In conclusion, there was an association of lower operator radiation dose in the thorax, abdomen, left eye, and right eye for tall operators as compared to regular height operators. We recommend regular height operators be exceedingly vigilant with their personal radiation protection techniques. Furthermore, these same protection techniques should be considered with patients that have a higher likelihood of generating greater dose-area-products.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:28Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation