A new digital tomosynthesis method with less artifacts for angiography.

P Haaker, E Klotz, R Koppe

    Medical Physics
    |July 1, 1985
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Comprehensive morphologic and functional imaging of heart transplant patients: first experience with dynamic perfusion CT.

    European radiology·2018
    Same author

    Bone mineral density and breast cancer risk: Results from the Vorarlberg Health Monitoring & Prevention Program and meta-analysis.

    Bone reports·2017
    Same author

    Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition.

    Physics in medicine and biology·2015
    Same author

    Volume perfusion CT (VPCT) for the differential diagnosis of patients with suspected cerebral vasospasm: qualitative and quantitative analysis of 3D parameter maps.

    European journal of radiology·2014
    Same author

    The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke.

    European radiology·2013
    Same author

    CT perfusion technique for assessment of early kidney allograft dysfunction: preliminary results.

    European radiology·2013
    Same journal

    Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

    Medical physics·2026
    Same journal

    Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

    Medical physics·2026
    Same journal

    Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

    Medical physics·2026
    Same journal

    Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

    Medical physics·2026
    Same journal

    Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

    Medical physics·2026
    Same journal

    Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

    Medical physics·2026
    See all related articles

    A novel nonlinear reconstruction method enhances tomographic imaging for sparse objects like contrast-filled blood vessels. This technique significantly reduces artifacts, enabling diagnostic image quality with fewer projections.

    Area of Science:

    • Medical Imaging
    • Image Reconstruction
    • Computational Imaging

    Background:

    • Tomosynthesis is a valuable imaging modality, but traditional reconstruction methods like back projection suffer from artifacts.
    • Reconstructing images from sparse data, particularly for "dilute" objects where most voxels have minimal absorption, remains a challenge.

    Purpose of the Study:

    • To introduce and evaluate a new nonlinear reconstruction method for tomosynthesis.
    • To assess the method's effectiveness for "dilute" objects, such as contrast-enhanced blood vessels.

    Main Methods:

    • Development of a novel nonlinear reconstruction algorithm tailored for sparse data.
    • Experimental validation using a wire phantom and a human heart specimen.

    Main Results:

    Related Experiment Videos

    • The nonlinear method demonstrated significantly reduced artifacts compared to back projection.
    • Diagnostic image quality was achieved with a minimal number of projections.
    • The algorithm's suitability for real-time hardware implementation was confirmed.

    Conclusions:

    • The proposed nonlinear reconstruction method offers a significant improvement for tomosynthesis of dilute objects.
    • This technique holds promise for enhanced medical imaging, potentially enabling faster and more accurate diagnoses.
    • The method's efficiency suggests feasibility for clinical application with dedicated hardware.