Related Experiment Video
Updated: Jun 14, 2025

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing
Callan M Gillespie1,2, Nicholas J Haas3, Tara F Nagle3
1Department of Biomedical Engineering and Lerner Research Institute, Cleveland Clinic Foundation, 2111 E 96th Street, Cleveland, OH 44106; Department of Applied Biomedical Engineering, Cleveland State University, 2111 E 96th Street, Cleveland, OH 44106.
Abstract:
To quantify the contributions of specific ligaments to overall joint movement, the principle of superposition has been used for nearly 30 years. This principle relies on using a robotic test system to move a biological joint to the same position before and after transecting a specific ligament. The resulting difference in joint forces is assumed to be the transected ligament's tension. However, the robotic test system's ability to accurately return the joint to the commanded pose is dependent on the compliance of the system's various components, which is often neglected. Accordingly, there were three objectives in this paper: (1) Explain the influence of system compliance on positioning error in superposition testing with a mathematical model, (2) Quantify the compliance of components within the robotic test system, and (3) Provide a framework to evaluate uncertainty in published superposition based in situ force measurements and demonstrate their implications on published anterior cruciate ligament (ACL) forces. A system stiffness model (SSM) was derived to explain that compliance of test system components will cause the superposition method to underestimate ligament tension and stiffness. Based on typical test system component and joint stiffness ranges measured in this study, it was determined that with decreasing robot and/or bone stiffness, or increasing joint stiffness values, ligament load error could increase to values greater than 50%. Results indicate that experimentalists should (1) maximize test system component stiffness relative to joint stiffness and/or (2) compensate for compliance induced deflection of the test system components.
Related Concept Videos
Method of Superposition
When applying the method of superposition, each type of load—whether...
Method of Joints
Since plane truss members are in the same plane, each joint is subjected to a coplanar and concurrent force system. To apply the method of joints, the first step is to...
Method of Joints: Problem Solving I
Method of Joints: Problem Solving II

