Related Experiment Video
Updated: May 16, 2025

07:36
High-Throughput Analysis of Optical Mapping Data Using ElectroMap
Published on: June 4, 2019
9.2K
Comparisons between sinus rhythm and paced maps using the 'one acquisition-two maps' technique
Deborah Foltran1, Maxime Beneyto1,2, Jean Timnou Bekouti1
1Department of Cardiology, University Hospital Rangueil, avenue Pr J Poulhès, 31400 Toulouse, France.
Abstract
No abstract available in PubMed .
Related Concept Videos
Graphical and Analytic Representation of Sinusoids
350
Analyzing two sinusoidal voltages with equal amplitude and period but different phases on an oscilloscope, an instrument used to display and analyze waveforms, involves a three-step process.
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
350
Pulse rhythm
725
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
725
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
710
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
710