Energy dependence of the GAFCHROMIC LD-V1 in the diagnostic radiographic modalities
Tatsuhiro Gotanda1, Tomoyuki Hasuo1, Shinnosuke Nishihara1
1Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Okayama, Japan.
Abstract:
The GAFCHROMIC LD-V1 radiochromic film is widely used in dosimetry because it can provide high-resolution two-dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low-energy range of mammography to the high-energy range of computed tomography. Net pixel value (NPV)-absorbed dose calibration curves for the GAFCHROMIC LD-V1 were generated using x-rays with effective energies of 18, 30, 50, and 80 keV to reflect those used in different diagnostic radiographic modalities. The film response was analyzed using calibration curves at each energy level. The coefficients of determination for the calibration curves at 18, 30, 50, and 80 keV were 0.9992, 0.9997, 0.9999, and 0.9976, respectively. The pixel value change at 30 keV was the largest and most sensitive, while the smallest change in pixel value and lowest sensitivity were noted at 18 keV. Because the energy dependence of the GAFCHROMIC LD-V1 is significant below 18 keV and above 80 keV, it is necessary to establish an appropriate NPV-absorbed dose calibration curve for energies below 18 keV and consider the possibility of underestimating the dose at energies above 80 keV.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...