Related Experiment Video
Updated: May 12, 2025

Digital Home-Monitoring of Patients after Kidney Transplantation: The MACCS Platform
Published on: April 12, 2021
Clinical Accuracy of Continuous Glucose Monitoring Immediately After Kidney Transplant in Patients With Type 2
Qurrat-Ul-Ain Aziz1, Kavita Batra2, Sanna Fatima1
1Department of Internal Medicine, Kirk Kerkorian School of Medicine, University of Nevada Las Vegas, Las Vegas, Nevada.
Objective:
To evaluate the accuracy of a blinded continuous glucose monitoring (CGM) device compared with point-of-care testing (POCT) and serum glucose measurements in the immediate postoperative period among kidney transplant recipients with type 2 diabetes mellitus (DM).
Methods:
In this prospective study, we enrolled 22 participants aged ≥18 years, with type 2 DM, immediately after kidney transplant. We applied a blinded CGM device that sampled interstitial glucose every 15 minutes and collected POCT and serum glucose values. Using matched pairs of glucose readings between CGM and POCT and between CGM and serum glucose, we calculated bias and absolute relative difference and conducted a Clarke Error Grid Analysis.
Results:
Eighty-two percent of the participants were male, with a mean age of 58 ± 9.69 years, mean body mass index of 30 ± 6.41 kg/m2, and baseline mean A1C level of 6.7 ± 1.07%. The mean durations of type 2 DM and end-stage kidney disease were 19 ± 10.6 and 3 ± 2.27 years, respectively. There were 327 and 72 matched pairs of CGM/POCT and CGM/serum glucose data, respectively. Clarke Error Grid Analysis comparing CGM/POCT showed 83.79% of values in zone A and 15.29% in zone B (combined 99.08%), with a mean absolute relative difference of 13.24%. For CGM/serum glucose, values of 83.1% were in zone A, and values of 16.9% were in zone B (combined 100%), with a mean absolute relative difference of 13.10%.
Conclusion:
CGM provided accurate blood glucose measurements compared with POCT and serum glucose values in patients with type 2 DM after kidney transplant. When used in this patient population, CGM devices have the potential to improve clinical outcomes through earlier detection and intervention for glycemic excursions.
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Diabetes: Symptoms, Diagnosis, and Complications
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...

