Related Experiment Video
Updated: May 10, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Balloon-expandable Versus Self-expanding Valves in Patients With Prior Surgical Mitral Valve Replacement Undergoing
Lluis Asmarats1, Pilar Jiménez-Quevedo2, Ignacio J Amat-Santos3
1Hospital Santa Creu i Sant Pau, Institut de Recerca Sant Pau (IR SANT PAU), Barcelona, Spain.
Background:
Pre-existing mitral prosthesis raises technical challenges for transcatheter aortic valve replacement (TAVR) but has been scarcely studied. In this work we sought to compare outcomes of patients with previous surgical mitral valve prostheses undergoing TAVR with balloon-expandable valve (BEV) or self-expanding valve (SEV) systems.
Methods:
Patients from the Spanish TAVR registry with pre-existing surgical mitral prostheses were included in this investigation. The primary endpoints were Valve Academic Research Consortium-3 technical and device success, with analysis according to valve type. Transcatheter heart valve (THV) embolization, mitral valve impingement, THV performance, and pacemaker findings were also assessed.
Results:
A total of 243 patients were included (37% BEVs, 63% SEVs). Overall technical success was 95.9%. Thirty-day device success was higher in BEV patients (94.4% vs 85.0%, P = 0.036), mainly driven by fewer incidences of moderate residual aortic regurgitation (0% vs 5.9%, P = 0.028) and THV embolization (0% vs 3.9%, P = 0.087). BEV recipients exhibited higher mean transvalvular gradients (10.5 vs 8.1 mm Hg, P = 0.002) and lower rates of permanent pacemaker implantation (5.6% vs 15.7%, P = 0.023). There were no differences in mortality, bleeding, or readmission at 30 days. In the multivariate analysis, a mitroaortic distance of ≤ 7 mm and lack of transesophageal echocardiography guidance were associated with increased device failure.
Conclusions:
In patients with pre-existing MV prostheses, TAVR was safe and effective regardless of the THV type. Nevertheless, the use of BEVs resulted in an increased rate of device success, driven by lesser THV embolization and residual aortic regurgitation.