Finite element analysis of welded titanium bar and poly ether ether ketone bar in maxillary full arch splinted
Lamiaa Farouk Zaki Mohamed1, Hebatallah Tarek Mohamed1, Hany Ibrahim Eid1
1Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, 11561, Egypt.
Abstract:
Full arch fixed provisional restorations are prone to fracture during function for several reasons. Those types of fractures during the healing period eliminate the cross-arch stabilization and disrupt stress distribution patterns. FEA (Finite Element Analysis) study was carried out using edentulous maxillary models where implants and other components were represented in three dimensional (3D) geometric models. Two 3D FEA models with six implants were used. Model TB: the implants were splinted with welded titanium bar; Model PB: the implants were splinted with PEEK (Poly Ether Ether Ketone) bar. An interim full arch PMMA (Poly methyl methacrylate) prosthesis was virtually designed for both models. Both models were subjected to vertical and oblique forces with a single force magnitude of 100 N. The amount of maximum equivalent Von-Mises stresses was calculated at the cervical part of the bone cylinder (marginal bone) and both frameworks. Under bilateral vertical loading, stresses were found to be comparable at the marginal bone between titanium and PEEK splinting. The PEEK framework had better and lower stress distribution than the titanium. While under unilateral oblique forces PEEK had better mechanical response on the marginal bone. And PEEK framework itself showed higher stresses than the titanium. The behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability.
More Related Videos
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Related Concept Videos
Torsion of Noncircular Members
Members Made of Elastoplastic Material
As the bending moment...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity