Related Experiment Video
Updated: Jul 5, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Vena contracta area measurement by three-dimensional echocardiography for assessing mitral regurgitation severity
Mehrnoush Toufan1, Dina Ashouri1, Sina Hamzehzadeh2
1Cardiovascular Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Background:
Echocardiography is the standard tool for the evaluation of mitral regurgitation (MR). Although Two-dimensional echocardiography is the most recommended tool, it has some limitations. Three-dimensional echocardiography (3DE) is suggested to overcome these limitations, however, it is more time-consuming. Introducing a simplified and accurate 3-D method could be helpful in this regard.
Methods:
Patients diagnosed with significant MR who were referred to Shahid Madani heart center, Tabriz, Iran for evaluation of MR severity were entered in this study. Patients with prior MR surgery, poor image quality, and without self-consent for participation in the study were excluded. Two-dimensional transthoracic echocardiography (TTE) and 3D transesophageal echocardiography (TEE) were performed in all patients. MR severity was compared between these two methods and between direct planimetry (DP) of the vena contracta area (VCA) and 3D directed multiplanar reconstruction (MPR).
Results:
A total of 53 patients were studied. Thirty-six (69.7%) of the patients were female. The mean age of patients was 66.21 ± 11.91 years. 3DVCA using DP was significantly correlated with the 2D method in terms of MR severity (p = 0.006). There was a significant correlation between the results of 3DE DP and 2DE magnetic resonance voiding cystography (MRVC) diameter (r = 0.503 and p = 0.0001). A significant correlation was also found between the result of DP and MPR-derived VCA using 3D (r = 0.97 and p = 0.0001).
Conclusion:
TEE is an invaluable method to decide the severity and mechanism of patients with MR, especially if TTE does not give adequate information. The method proposed in this study for evaluation of MR severity and mechanism using 3D TEE could be a helpful option, especially in the above-mentioned conditions. In this study, 3D direct planimetry had an acceptable correlation with 2DE MRVC and also with 3D MPR-derived VCA.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...