Related Experiment Video
Updated: May 13, 2025

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Influence of CYP1B1 Variants on Phenotypic Characteristics and Therapeutic Outcomes in Primary Congenital Glaucoma
Rita Rodrigues1, David Alves1, João Esteves-Leandro1
1Department of Ophthalmology, Unidade Local de Saúde de São João, Porto, Portugal.
Purpose:
To identify CYP1B1 variants in primary congenital glaucoma (PCG) patients from Northern Portugal and examine genotype-phenotype correlations.
Design:
Cross sectional observational study.
Participants:
Seventy-one patients diagnosed and treated for PCG at ULS São João, Porto, Portugal, were included. These patients met the following criteria: available genetic testing data, a minimum follow-up period of 1 year, and the last appointment between January 2022 and January 2024.
Methods:
Demographic and clinical data were collected. CYP1B1 variants were screened using DNA sequencing. A next-generation sequencing (NGS) glaucoma panel was performed in patients with heterozygous or absent CYP1B1 variants in the screening. Genotype-phenotype correlations were assessed by comparing clinical characteristics between patients with identified biallelic plausible disease-causing variants in CYP1B1 variants and those with negative genetic testing results.
Main Outcome Measures:
CYP1B1 variants, sex, laterality, age at diagnosis, age at first surgery, number of surgical procedures, number of intraocular pressure (IOP)-lowering medications, IOP at last follow-up, and final best-corrected visual acuity (BCVA).
Results:
Sixty-six unrelated probands and 5 affected relatives (133 eyes) were analyzed. Two plausible disease-causing CYP1B1 variants were identified in 60.6% (43/71) of patients. Nineteen distinct CYP1B1 variants were identified, including 4 novel variants. The most frequent variants were c.535del (43.5%) and c.1200_1209dup (28.2%). Compared with negative genetic testing group (n = 22), patients with CYP1B1 variants (n = 43) showed significantly higher rates of bilateral disease (100% vs. 68%, P < 0.001), earlier disease onset (median 0 vs. 5.5 months, P < 0.001), poorer final BCVA (median 0.5 vs. 0.25 logarithm of the minimum angle of resolution, P = 0.025), higher IOP at last follow-up (median 16 vs. 12 mmHg, P < 0.001), and greater need for surgical interventions (median 2 vs. 1, P = 0.014) and IOP-lowering medications (median 2 vs. 0, P = 0.005). Next-generation sequencing testing in CYP1B1-negative patients identified 3 novel heterozygous variants of uncertain significance in the TEK gene.
Conclusions:
Primary congenital glaucoma patients from Northern Portugal with CYP1B1 variants are more likely to present with bilateral disease, earlier onset, and a more severe clinical phenotype, suggesting a strong genotype-phenotype correlation.
Financial Disclosure(S):
The authors have no proprietary or commercial interest in any materials discussed in this article.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Genetic Lingo
Nonlinear Pharmacokinetics: Dependence of Elimination Half-Life and Dose Clearance
A study on guinea pigs examined the...
Photoreceptors and Visual Pathways

