Related Experiment Video
Updated: Jul 1, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Outcomes of Percutaneous Coronary Interventions Following Transcatheter Aortic Valve Replacement: Insights From the
Christina Lalani1, Ravi K Sharma2, Jonathan Sevilla-Cazes3
1Division of Cardiology, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
Insights
Transcatheter aortic valve replacement (TAVR) patients undergoing percutaneous coronary intervention (PCI) had similar procedural success but higher risks of stroke, bleeding, and repeat PCI compared to non-TAVR patients. These findings highlight potential challenges in coronary access post-TAVR.
Area of Science:
- Cardiovascular Interventions
- Interventional Cardiology
- Health Services Research
Background:
- Transcatheter aortic valve replacement (TAVR) devices may complicate coronary artery access.
- Limited real-world data exist comparing percutaneous coronary intervention (PCI) outcomes in post-TAVR versus non-TAVR patients.
Purpose of the Study:
- To compare procedural characteristics and outcomes of PCI in patients with and without a history of TAVR.
- To evaluate the incidence and outcomes of PCI following TAVR in a real-world setting.
Main Methods:
- Utilized Medicare claims data (2011-2017) to assess PCI incidence post-TAVR.
- Employed the CathPCI Registry to compare PCI outcomes between 1,309 post-TAVR patients and 5,236 propensity score-matched non-TAVR patients.
Main Results:
- Procedural success for PCI was similar between post-TAVR and non-TAVR groups.
- Post-TAVR patients experienced longer fluoroscopic times (21.9 vs 17.7 min) and higher rates of post-procedural stroke (0.8% vs 0.4%) and bleeding (5.1% vs 2.9%).
- Post-TAVR patients had increased likelihood of repeat PCI (HR: 1.36), stroke (HR: 1.65), and death (HR: 1.23) within 3 years post-PCI.
Conclusions:
- PCI in patients with a TAVR history shows similar procedural success but increased procedural complexity and adverse events.
- Higher rates of stroke, bleeding, and repeat PCI necessitate careful consideration in post-TAVR patients requiring coronary intervention.
- Findings underscore the importance of managing coronary access and outcomes in the TAVR population.
Abstract:
Although transcatheter aortic valve replacement (TAVR) devices can impair coronary access, there are limited real-world data comparing outcomes of percutaneous coronary intervention (PCI) in post-TAVR versus non-TAVR patients. In this study, we compare procedural characteristics and outcomes between patients with versus without a history of TAVR who undergo PCI. We used claims data for the Medicare population to evaluate the incidence of PCI after TAVR between 2011 and 2017. Then, using the CathPCI Registry, we compared PCI outcomes between patients with a history of TAVR versus propensity score-matched non-TAVR patients. Of the 52,780 Medicare patients who underwent TAVR between 2011 and 2017, the incidence of acute myocardial infarction (AMI) was 10.2% and of PCI was 5.1% at 5 years. At 5 years, the incidence of stroke was 5.0% and of death was 64.0%. In the CathPCI Registry, procedural success for PCI was similar between 1,309 post-TAVR patients versus 5,236 propensity-score matched patients without prior TAVR. However, post-TAVR patients required greater fluoroscopic time (21.9 vs 17.7 minutes, p <0.001) and had higher rates of post-procedural stroke (0.8% vs 0.4%, p = 0.02) and bleeding (5.1% vs 2.9%, p <0.001). Post-TAVR patients were more likely to have repeat PCI in the 3 years post-PCI (HR: 1.36, 95% C.I: 1.09, 1.70) and had higher rates of stroke (HR: 1.65, C.I.: 1.07 to 2.56, p = 0.023) and death (HR: 1.23, C.I.: 1.11-1.38, p <0.001) compared to non-TAVR patients. In conclusion, in the CathPCI Registry, patients with a history of TAVR appeared to have similar procedural success but longer fluoroscopic times, more frequent post-procedural bleeding and stroke, and a higher likelihood of a repeat PCI compared with matched patients without a history of TAVR.
More Related Videos
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Coronary Artery Disease V: Interprofessional Care
Peripheral Artery Disease III: Interprofessional Care