Related Experiment Video
Updated: May 14, 2025

Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Severe primary graft dysfunction after heart transplant: trends and outcomes in a contemporary Spanish cohort
Carlos Ortiz-Bautista1, Luis Almenar-Bonet2, David Couto-Mallón3
1Servicio de Cardiología, Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Hospital Universitario Gregorio Marañón, Madrid, Spain; Facultad de Medicina, Universidad Complutense, Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III, Madrid, Spain.
Introduction And Objectives:
Severe primary graft dysfunction (PGD) is the leading cause of early mortality following heart transplant (HT). This study analyzed the temporal trends and mortality associated with severe PGD, identified risk factors, and developed a predictive model based on a contemporary cohort.
Methods:
A total of 2029 HT performed between 2010 and 2020 in 14 Spanish centers were retrospectively analyzed. Patients with and without severe PGD were compared. Logistic regression was used to identify predictors of severe PGD and to generate a risk score. Model performance was assessed in terms of calibration and discrimination.
Results:
The incidence of severe PGD was 10%, with an increase observed over the last 5 years (8% vs 11%). However, 30-day and 1-year mortality declined significantly (59.1% vs 38.8% and 69.7% vs 58.8%, respectively). Independent predictors of severe PGD included extracorporeal membrane oxygenation (OR, 2.79), pretransplant ventricular assist devices (OR, 2.11), donor-to-recipient weight ratio <0.8 (OR, 2.11), and congenital heart disease (OR, 2.11). A risk score was created, showing good calibration but limited discriminative ability.
Conclusions:
Despite a rising incidence of severe PGD, mortality showed a marked decrease. Predictors of severe PGD included congenital heart disease, a donor-to-recipient weight ratio <0.8, and the use of extracorporeal membrane oxygenation or pretransplant ventricular assist devices. The predictive model showed good calibration but only moderate discriminative performance.