Related Experiment Video
Updated: May 16, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Unveiling the flexural strength of corroded prestressed self compacting concrete beams enhanced with M-sand and
Yamuna Bhagwat1, Gopinatha Nayak2
1Department of Civil Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
Abstract:
Prestressing steel corrosion is one of the barriers to the serviceability of prestressed concrete structures. The presence of aggressive environmental conditions leads to a reduction in the efficiency of the structures by degradation. Hence, untimely deterioration of the structures before completion of the expected service life is of great concern for engineers and researchers. The development of corrosion is faster and more severe in prestressed steel than in normal steel because of the high stress in prestressing steel. Therefore, a detailed investigation of the prestressed concrete structure under a corrosive environment is essential. This particular study focused on studying the corrosion effect on flexural behaviour of prestressed self compacting concrete beams made of M40 and M60 grade mixes using M-sand as fine aggregate, also with and without polypropylene fibre. The beam specimens were artificially corroded by the accelerated corrosion method, and the flexural strength of the corroded and non corroded prestressed concrete beam specimens were studied under four point bending method. The comparison study of prestressed concrete beams with and without polypropylene fibre showed that corrosion levels obtained in the corroded prestressed concrete beam specimens with fibre were less than the corroded prestressed concrete beam specimens without fibre at a constant period with a constant current. The corrosion levels obtained in M60 self compacting concrete were less than that of M40 self compacting concrete specimens. Also, corrosion of the strand reduced the cracking load, ultimate load, ultimate deflection, energy absorption capacity and stiffness of prestressed concrete beam specimens. The study concludes that the addition of polypropylene fibre to the self compacting concrete mixes improves the corrosion resistance of prestressed concrete beam and the flexural performance of the corroded prestressed concrete beam.
Related Concept Videos
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Reinforcements in Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Prestressed Concrete
Fatigue Strength of Concrete

