Dexcom G7 Accuracy and Reproducibility in the Intensive Care Unit
Jesica D Baran1, Charles Spanbauer2, Rajlaxmi Bais1
1University of Washington, Seattle, Washington, USA.
Abstract:
Objective: To evaluate the accuracy of Dexcom G7 continuous glucose monitor (CGM) in the intensive care unit (ICU) setting. Methods: We performed a prospective, single-center study in patients with known diagnosis of diabetes or stress hyperglycemia and treated with insulin. Two Dexcom G7 sensors were placed on the abdomen and/or upper arm. Blood glucose (BG) measurements obtained according to usual ICU care were paired with sensor glucose values, and accuracy metrics were analyzed. For further comparison, non-ICU patients were also studied. Results: The analyses included 30 participants with mean ± standard deviation age of 55 ± 12 years, with preexisting diabetes in 40% and stress hyperglycemia in 60%. A total of 1515 sensor-BG pairs were analyzed. The mean difference (bias) was -12 mg/dL (median: -6), and the mean relative absolute difference (RAD) was 16% (median: 12%). Mean RAD was 13% (median: 9%) using plasma glucose as the reference and 17% (median: 13%) using capillary glucose. For comparison, in 35 adults with type 2 diabetes in a non-ICU setting, the mean RAD was 15% (median: 13%). No meaningful differences were observed across the duration of time since sensor insertion. No correlation was found between mean RAD and severity of illness. Conclusions: Mean RAD of the Dexcom G7 sensor in the ICU setting was slightly higher than the outpatient use labeling, but was similar to a non-ICU hospital setting. Further studies are needed to determine whether CGM can be used nonadjunctively in an ICU setting for insulin management, including use of glucose trends and alarms for hypoglycemia or hyperglycemia.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Uncertainty in Measurement: Accuracy and Precision
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.