Related Experiment Video
Updated: Jul 29, 2026

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Standardization of Lung CT Number Using COPD Gene2 Phantom Under Various Scanning Protocols
Hoondong Song1, Hanjoo Jang2, Jongduk Baek2,3
1School of Integrated Technology, Yonsei University, Incheon 21983, Republic of Korea.
Standardizing lung CT scans for chronic obstructive pulmonary disease (COPD) diagnosis is crucial. A new method using solid foams instead of water reference improves CT number standardization reliability and consistency for better lung tissue analysis.
Area of Science:
- Medical Imaging
- Radiology
- Pulmonary Medicine
Background:
- Lung computed tomography (CT) is vital for diagnosing chronic obstructive pulmonary disease (COPD) by assessing lung tissue destruction.
- Accurate standardization of CT numbers is essential for distinguishing healthy from damaged lung tissue.
- Previous standardization methods using water as a reference have shown limitations due to variability.
Purpose of the Study:
- To improve the reliability and consistency of CT number standardization for lung CT images.
- To develop a modified standardization method for COPD diagnosis that overcomes the limitations of water-based references.
Main Methods:
- Modified a CT number standardization method by excluding water and using only solid foams from the COPD gene2 phantom as references.
- Collected 234 CT images from 8 different CT scanners using the COPD gene2 phantom.
- Analyzed CT number standard deviations and variations to evaluate the proposed method's performance.
- Segmented the dataset by CT dose index (CTDI), X-ray tube potential, and reconstruction algorithms to assess protocol impact.
Main Results:
- The modified method demonstrated improved reliability and consistency in CT number standardization compared to previous approaches.
- Excluding water as a reference significantly reduced variability in CT number standardization.
- Analysis of different scanning protocols provided insights into their impact on standardization accuracy.
Conclusions:
- The proposed modification of excluding water and using solid foams enhances the robustness of CT number standardization for lung CT imaging.
- This improved standardization is critical for accurate COPD diagnosis and lung tissue evaluation.
- Further analysis of scanning parameters can optimize the standardization process for diverse clinical settings.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024