Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Green Analytical Method Using Single-Drop Microextraction Followed by Gas Chromatography for Nitro Compound Detection
Tamara Pócsová1, Senad Okanovič1, Svetlana Hrouzková1
1Faculty of Chemical and Food Technology, Institute of Analytical Chemistry, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovakia.
Abstract:
The extensive use of nitro compounds in agriculture, industry, armaments, and pharmaceuticals, along with their toxic effects on living organisms, necessitates efficient and environmentally sustainable analytical methods. Traditional extraction techniques often involve practices that are not eco-friendly, such as the use of large volumes of solvents, toxic chemicals, and the generation of significant waste; therefore, the single-drop microextraction technique was involved in overcoming these limitations. This study shows an environmentally friendly method for nitro compound analysis focusing on NB (Nitrobenzene), 2-NT (2-Nitrotoluene), 3-NT (3-Nitrotoluene), 4-NT (4-Nitrotoluene), 1,3-DNB (1,3-Dinitrobenzene), 1,2-DNB (1,2-Dinitrobenzene), 2,4-DNT (2,4-Dinitrotoluene), and TNT (Trinitrotoluene). To separate and to detect selected nitro compounds, gas chromatography with an electron capture detector was utilized, which is highly selective for analytes containing nitro groups. To determine optimal experimental conditions, extraction parameters were studied, including the impact of salt addition, temperature, and pH on extraction efficiency. Key performance parameters, such as limit of detection (LOD), limit of quantification (LOQ), repeatability, extraction recoveries, calibration range, and matrix effects, were assessed. The LOD values ranged from 0.01 to 0.09 μg/L in deionized water, 0.01 to 0.06 μg/L in tap water, 0.01 to 0.03 μg/L in seawater, and 0.03 to 0.11 μg/L in model forensic rinse water. The optimized method was successfully applied to the determination of nitro compounds in real environmental water samples and forensic rinse water samples. The environmental sustainability and greenness of the proposed method was evaluated with the AGREE, AGREEprep, and AESA techniques.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...