Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Assessment of Roll-Over Test in Preeclamptic and Healthy Pregnant Women Using Arterial Stiffness
Szilárd Szatmári1, Dániel T Nagy1, Bence Kozma2
1Department of Anesthesiology and Intensive Care, University of Debrecen Faculty of Medicine, 4032 Debrecen, Hungary.
Abstract:
Background: The early recognition of systemic hemodynamic changes resulting from uteroplacental circulation disturbance in preeclampsia (PE) is of great importance for its appropriate treatment and prevention. The aim of the present study was to assess the hemodynamic changes during a roll-over test in healthy normotensive and preeclamptic pregnant women using applanation tonometry. Patients and methods: Healthy pregnant and PE women in their third trimester were studied. First, applanation tonometry was performed in a resting state on the right radial artery of each subject. In the second phase, the measurements were repeated in the left-lateral position and 5 min after turning each patient into a supine position (roll-over test = ROT). The systolic and diastolic central and peripheral blood pressures, pulse pressures, and augmentation index (AIx75) values were registered for all phases. Results: A total of 21 PE and 14 healthy pregnant women entered this study. At rest, the PE patients had higher systolic, diastolic, and mean blood pressures; the preeclamptic patients had higher peripheral and central blood pressure and pulse pressure values compared to the healthy controls. A statistically significant difference was found between the augmentation index (AIX-75) values for the preeclamptic and healthy pregnant women (healthy pregnant: 9.0 ± 2.4 vs. preeclamptic: 18.9 ± 6.0; p = 0.019). During the ROT, no significant differences could be detected in the applanation tonometry parameters within the groups. The differences between the PE and healthy pregnant women continued to exist in the left-lateral and supine positions during the roll-over test. Conclusions: This is the first study combining a roll-over test and arterial stiffness measurements in healthy pregnant females and in those with PE. Although we can confirm that arterial stiffness measurements can be used to detect hemodynamic changes in pregnant women with PE, combining it with a roll-over test is unsuitable for improving the method's sensitivity.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure