A 3D printed cryogenic device for gas chromatography: Design, and performance demonstrated for multidimensional and
Ian A Wittman1, Tom Jarvis2, Milton T W Hearn3
1Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton, VIC 3800, Australia.
Abstract:
This paper describes the development of a device 3D printed using stainless steel that is intended to operate as a cold trapping assembly when cooled by liquid CO2, in a manner similar to a longitudinally modulated cryogenic system (LMCS). The cold trap enclosure design is detailed, and the system's performance is tested to assess its suitability for use as a collection and rapid re-mobilisation device for gas chromatography analysis of volatile organic compounds (VOC). Precision of modulation period timing was evaluated, showing a maximum error of 8 μs and an average variation of <1 ns across 10,000 successive modulations. The system's trapping capabilities were tested using an alkane series (C5-C9), successfully trapping all analytes and producing peaks with full width at half height (FWHH) as low as 65 ms. Maximum trapping time was assessed for hexane, with the modulator retaining the compound for up to 9 s in a 100 °C oven before breakthrough was observed. The modulator was then applied to investigate enantioselective separation of limonene. Whilst a single chiral column was used, various lengths (20 cm - 5.0 m) of column were drawn through the modulator, where these lengths effectively function as enantioselective second dimension (2D) columns. Injected (R,S)-limonene enantiomers were collected as a single entity, then rapidly released to the 2D column. Comprehensive two-dimensional gas chromatography was demonstrated to be viable using the 3D printed modulator for a tea tree oil sample.
More Related Videos
08:12Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids BPCA
Published on: May 16, 2016
08:59Cryo-Electron Microscopic Grid Preparation for Time-Resolved Studies using a Novel Robotic System, Spotiton
Published on: February 25, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: