Less is more? Performance of loops without distributed capacitors for 7 T MRI applications
G Costa1, M M Paulides2, S Güler3
1Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
None:
We present an exploration of loops without distributed capacitors (i.e. plain loops) for their suitability as RF coils in 7 T MRI applications. Herein, we report on the differences between a circular -i.e. round- plain loop, an elliptic -i.e. elongated- plain loop, a conventional loop - i.e. a loop with distributed capacitors - and a dipole. This comparison highlights the benefits and limitations of plain loops, providing insights into their viability as an alternative to more complex coil designs for the construction of RF coil arrays at 7 T. We characterized the coils in terms of surface current distribution, robustness to loading, transmit efficiency, maxSAR10g, coupling, and "flexibility" - defined as the ability of a coil to stay tuned (S11≤-10dB) after mechanical deformation at a constant distance from the load. Additionally, we discussed the best practice to fabricate plain loops. A 12 cm round plain loop was more sensitive to the coil load distance than a conventional loop, but it was flexible and can be operated at a roughly constant distance from different patients. The antenna showed similar transmit properties to a 12 cm round conventional loop but with lower coupling (∼44 % less) when the loops were gapped or overlapped less than 20 %. A 62 mmx280mm elongated plain loop was more robust than a dipole to the coil-load distance, providing similar transmit efficiency for imaging of the prostate, with lower worst case maxSAR10g (∼25 % less), but higher coupling (S21 ∼ -15 dB). This paper provides the groundwork for further optimizing plain loops in UHF-MRI coil arrays.
More Related Videos
08:51Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
Related Concept Videos
Magnetic Field Of A Current Loop
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Magnetic Resonance Imaging
Capacitors in Series and Parallel
Suppose the capacitors are connected one after the other such that the negative terminal of the first connects to the positive terminal of the...
Capacitors
When a voltage source is connected to a capacitor, positive and negative charges accumulate on the opposite plates. This accumulation generates a potential difference that equals the product of the...