Related Experiment Video
Updated: May 17, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Structural analysis of ferrocement composite panels with expanded perlite based mortar
Zhengyu Wu1,2,3,4, Amirhossein Madadi5,6, Tzuyang Yu7,8,9
1School of Engineering, Fujian Jiangxia University, Fuzhou, 350108, Fujian, China.
Abstract:
A laboratory investigation was conducted to evaluate the structural behavior of ferrocement composite panels (FCPs) incorporating expanded perlite lightweight aggregate (LWA) at varying volume fractions (55%, 35%, and 15%). Twelve lightweight FCPs (60 × 60 × 4 cm) were fabricated with one, two, or three layers of expanded rib lath and tested under three-point flexural loading. Structural response was assessed using digital image correlation (DIC) and theoretical analysis based on the thin plate theory. The results showed that increasing the number of rib lath layers significantly enhanced the first crack load (Fcr) and ultimate load (Fu), with improvements ranging from 11 to 224% in Fcr and 18 to 76% in Fu. Deflection at first crack ([Formula: see text]) and ultimate load ([Formula: see text]) increased by an average of 47% and 229%, respectively. Additionally, the use of perlite LWA increased [Formula: see text] and [Formula: see text] by 29% and 26% compared to regular FCPs, highlighting its effectiveness in enhancing flexibility. DIC analysis identified transverse strain (εxx) as the most sensitive parameter for early crack detection. Taguchi optimization further revealed that the number of rib lath layers had a more significant impact on Fcr and Fu than perlite content. These findings suggest that a three-layer FCP system with 15% perlite replacement optimizes load-bearing capacity, making it well-suited for high-strength, lightweight applications such as modular buildings and prefabricated structural elements.
More Related Videos
Related Concept Videos
Ferrocement
Composite Masonry Walls
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Fiber Reinforced Concrete
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Reinforced Brick Masonry
To fortify brick walls...

