Behavior of turnout sleepers in a large-scale ballast box test
Gernot Grohs1, Paul Pircher2, Martin Quirchmair3
1Institute of Railway Infrastructure Design, Graz University of Technology, Graz, Austria. grohs@tugraz.at.
Abstract:
Turnouts are essential components of the railway infrastructure. Their sleepers change in length leading to asymmetric loading and structural discontinuities. This accelerates ballast wear and sleeper settlement creating challenges for maintaining track geometry and safety. Understanding load transfer from sleepers to ballast is key to improve railway durability and performance. This study examines the settlement behavior of turnout sleepers and the pressure distribution beneath them in a large-scale laboratory ballast box test. Cyclic loading tests were conducted on a long concrete sleeper with and without under sleeper pads (USP) to compare their load transfer characteristics and settlement behavior. For this laser displacement sensors and pressure mapping sensors (Getzner Sensor Sleeper technology) were used. A vertical cyclic load, oscillating between 5 kN and 160 kN at frequencies of 3 Hz to 5 Hz, was applied to one side of the turnout sleeper, while a constant load of 10 kN was applied to the opposite side to represent the structural stiffness of the turnout. For each test configuration more than four million load cycles were carried out. The sleeper showed a degressive settlement pattern with asymmetric distribution. The use of USP resulted in more uniform and gradual settlement, more uniform pressure distribution and reduction of pressure peaks over time. Additionally, the sleeper deformation caused by the load was mitigated and the occurrence of voids underneath the sleeper was significantly reduced. The sleeper with elasto-plastic USP show larger initial oscillation amplitudes due to the pad’s elasticity, which stabilizes over time.
Related Concept Videos
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Vebe Test
To conduct the test, concrete is placed into the slump cone. The concrete is filled in layers and...