Evaluating Orthophosphate-Silicate Blend as an Alternative to Blended Phosphates for Corrosion Control and
Kalli M Hood1, Benjamin F Trueman1, Graham A Gagnon1
1Centre for Water Resource Studies, Department of Civil and Resource Engineering, Dalhousie University, 1360 Barrington Street, Halifax, Nova Scotia B3H 4R2, Canada.
Abstract:
The presence of iron and manganese in drinking water distribution systems can contribute to discoloration, taste and odor issues, scale buildup, deposition corrosion, and the adsorption and transport of lead. Sequestrants can minimize aesthetic concerns and scale buildup, but they are risky due to increased lead/copper solubility. Here, we used a bench-scale batch reactor to evaluate orthophosphate with sodium silicate or polyphosphate for simultaneous lead corrosion control in waters with and without iron/manganese. Consistent with previous work, ortho-trimetaphosphate increased the total lead (23%). Increased dissolved lead was also observed for both ortho-trimetaphosphate (50%) and ortho-silicate (30%) treatments. When iron/manganese was present, orthophosphate-silicate was associated with 5-12% less total lead relative to orthophosphate under the same conditions, and the effect of ortho-trimetaphosphate was pH dependent. The addition of silicate and trimetaphosphate also reduced water discoloration compared to orthophosphate, as measured by apparent color. Here, the orthophosphate-silicate blend did not significantly increase total lead in the absence of high iron and manganese but increases to the highly mobile, dissolved fraction should be noted. Utilities seeking to control lead for compliance purposes, while simultaneously managing iron and manganese for consumer confidence, should explore orthophosphate-silicate as a possible solution in their corrosion control assessments.
Related Concept Videos
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Sulfate Attack on Concrete
Sulfates from sources like soil, groundwater, or industrial effluents...
Corrosion
Pozzolans
Fly ash is...