The hidden toxicity of solid phase extraction blanks in water analysis

Yan Wang1, Mafalda Castro1, Selina Tisler1

  • 1Department of Plant and Environmental Sciences, University of Copenhagen, Frederiksberg, Denmark.

Summary

Non-toxic blank samples are crucial for Effect Directed Analysis (EDA). This study identified elution solvents and SPE materials as sources of toxicity, offering solutions to ensure accurate environmental sample analysis.

Related Concept Videos

Blank Solutions00:56

Blank Solutions

A blank solution is a solution that does not contain the analyte, or the substance of interest being tested or measured. It is typically prepared using the same reagents and procedure as the sample solution but without adding the analyte. The primary purpose of preparing a blank solution is to account for any background interference or contamination that may affect the accuracy and reliability of the analytical method.
In some experimental cases, the reagents, solvents, or lab equipment used in...
203
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
336
Sample Preparation for Analysis: Overview01:21

Sample Preparation for Analysis: Overview

Sample preparation is an essential step in the analytical process. It involves preparing a sample so that it can be analyzed accurately. The goal is to extract the analyte, the substance you want to measure, from the sample while removing any components that may interfere with the analysis. Sample preparation techniques vary depending on the physical state of the sample.
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
171
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
537