Related Experiment Video
Updated: May 17, 2025

Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Prediction of pH Gradient Elution of Ion Exchange Chromatography for Antibody Charge Variants Separation Based on
Yu-Xin Liao1, Ce Shi1,2, Xue-Zhao Zhong2
1Key Laboratory of Biomass Chemical Engineering of Ministry of Education, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, China.
Abstract:
Mechanistic modeling of ion exchange chromatography (IEC) is a promising technique to improve process development. However, when considering the pH influence, model prediction becomes challenging due to the multiple pH-dependent parameters and complex interactions. In order to more effectively predict the pH gradient elution behavior, a two-step model calibration strategy was proposed for the pH-dependent steric mass action (SMA) model with the empirical correlations of characteristic charge ν and equilibrium coefficient keq. The strategy was verified through a case study of monoclonal antibody charge variants purification with IEC. All nine calibration experiments were conducted using linear salt gradient elution at three fixed pH values. The average root mean square error (RMSE) was 14.28% between the model calculation and experiments. Both ν and ln(keq) exhibited good linear correlations with pH (R2 > 0.99). Then, the well-calibrated pH-dependent SMA model showed a satisfactory capability for predicting the pH gradient elution behaviors with an RMSE of 16.18%. Moreover, the model was used for process optimization under different elution modes, including salt gradient, pH gradient, and salt-pH dual gradient, improving the yield from 70.07% to 74.91%. The optimized linear pH gradient elution was verified by experiment (RMSE = 8.30%). Finally, a methodological framework for utilizing the simplified pH-dependent SMA model developed in this work was summarized to explore its practical applications. The two-step calibration strategy proposed significantly alleviates the workload for the pH-dependent IEC modeling. The model-based process optimization effectively enables faster pH-dependent process development with minimal experiments.
More Related Videos
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Related Concept Videos
Ion Exchange
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Electrophoresis: Overview
There...