Related Experiment Video
Updated: May 6, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Safe Use of High-Flow Oxygenation During Transoral Laser Microsurgery Without Airway Fire: A Review of 369
Nathaniel S Neptune1, Jeanne L Hatcher1, Jeremy S Collins2
1Department of Otolaryngology-Head and Neck Surgery, Emory University School of Medicine, Atlanta, Georgia, USA.
Objective:
Transnasal humidified rapid-insufflation ventilatory exchange (THRIVE) is often avoided during intraoral laser use due to the concern for an airway fire with the addition of high-flow oxygen. We aim to demonstrate that THRIVE can be safely used during transoral laser microsurgery (TLM) without causing an airway fire or other major complications.
Study Design:
Retrospective cohort study.
Setting:
Emory University Hospital Midtown between January 2020 and April 2024.
Methods:
A retrospective chart review of all patients who underwent TLM with the use of THRIVE was performed. A standardized laser safety protocol was followed, and either a carbon dioxide or potassium titanyl phosphate laser was used for all cases.
Results:
In total, 369 cases were examined, and no fire, ignition, flash, or major complication occurred. In total, 270 (73.2%) patients were Caucasian females and 271 (73.4%) patients had a primary diagnosis of idiopathic subglottic stenosis. A total of 110 (29.8%) cases were completed with the use of THRIVE alone, 238 (64.5%) required the addition of jet ventilation, and 21 (5.7%) required intubation for the completion of the case. Increased body mass index was positively associated with the need for jet ventilation or intubation and reached statistical significance for the type of airway management employed during the case (P-value < .001).
Conclusion:
Airway fire and other major complications are preventable with the use of THRIVE during TLM if standardized laser safety practices are implemented.
More Related Videos
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management