Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Evaluation of the accuracy of a low-cost external tocodynamometer in a pilot study in Malawi
Alex Kortum1, Christina Samuel2, Theresa Sonka2
1Department of Bioengineering, Rice University, Houston, Texas, United States of America.
Abstract:
Uterine contraction monitoring during labor has been linked to improved maternal outcomes. However, performing this monitoring can be challenging for financial and logistical reasons in low resource settings. This proof-of-concept study aimed to compare the accuracy of a low cost external tocodynamometer we developed to that of a commercially available external tocodynamometer. In total, 60 patients with anticipated vaginal deliveries at a hospital in Blantyre, Malawi were enrolled. Both the research device and the commercial device were secured to the patients, and traces were recorded simultaneously from each device. Trace pairs were split into 10 minute segments, and contraction locations were independently annotated on a selection of 75 contemporaneous trace pairs from 38 out of 60 patients by two expert clinicians. In total, 484 contractions were marked on the research device, and 465 contractions were marked on the commercially available device, 312 of which were marked consistently on both devices. The average consistency of marked contractions on the same device between the two observers was 0.89 for the research device compared with 0.84 for the commercially available device. The average consistency between the two devices using a 10-patient rolling average increased from 0.50 at the beginning of the study to 0.64 at the end. The annotated traces from the two devices suggested the same clinical management 72% of the time. The research device displayed reasonable agreement with the commercially available tocodynamometer in detecting contractions. The increase in the measured consistency over the course of the study suggests that improving usability of the device to ensure better positioning on the patient could result in improved performance. Further studies assessing the accuracy and usability of the device are needed.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure