Related Experiment Video
Updated: May 20, 2025

11:26
Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
12.3K
Brain pulsation demonstrated by CSF flow artifacts on FLAIR images might be associated with brain function
Toshio Imaizumi1, Kengo Suzuki1, Kyoya Sakashita1
1Department of Neurosurgery, Kushiro City General Hospital. 1-12 Shunkodai, Kushiro, Hokkaido 085-0822, Japan.
European Journal of Radiology
|May 17, 2025
Summary
Reduced brain pulsation, measured by cerebrospinal fluid (CSF) flow artifacts, is linked to cognitive decline and frontal lobe dysfunction. This suggests brain pulsation is vital for glymphatic system function and overall brain health.
Area of Science:
- Neuroscience
- Radiology
- Gerontology
Background:
- The glymphatic system clears brain waste products, and its dysfunction is linked to cognitive impairment.
- Brain pulsation, visualized as cerebrospinal fluid (CSF) flow artifacts on FLAIR imaging, is a key driver of glymphatic function.
- Understanding factors influencing brain pulsation is crucial for diagnosing and potentially treating cognitive decline.
Purpose of the Study:
- To investigate factors associated with human brain pulsation.
- To correlate brain pulsation levels with cognitive function and neuroradiological findings.
Main Methods:
- Quantified CSF flow artifact scores across eight brain regions in 1,000 adults using FLAIR imaging.
- Assessed total CSF flow scores (0-16) and analyzed associations with cognitive tests and anatomical measurements.
- Employed multivariate logistic regression to identify risk factors and neuroradiological correlates of reduced brain pulsation.
Main Results:
- The mean CSF flow score was 12.8 ± 1.6.
- Lower brain pulsation (score ≤11) correlated positively with poorer performance on a 100-7 cognitive test and greater frontal polar-cranium distance.
- Reduced brain pulsation was negatively associated with female gender and linked to frontal lobe function during calculations.
Conclusions:
- Brain pulsation, visualized via CSF flow artifacts, is associated with frontal lobe function and cognitive performance.
- Reduced brain pulsation may indicate glymphatic system disturbance and contribute to cognitive impairment.
- FLAIR imaging of CSF flow artifacts offers a potential method to assess brain pulsation and its impact on brain health.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
4.9K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
4.9K
Cerebrospinal Fluid
1.7K
Cerebrospinal fluid (CSF) is a colorless liquid that flows around the brain and the spinal cord, playing a vital role in the protection, support, and overall function of the central nervous system (CNS). CSF production, circulation, and absorption are tightly regulated processes essential for the brain and spinal cord to function properly.
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
1.7K

