Related Experiment Video
Updated: May 21, 2025

Continuous Hydrologic and Water Quality Monitoring of Vernal Ponds
Published on: November 13, 2017
Community-Wide Monitoring of Lead in Drinking Water Distribution Systems Using Hand-Held Voltammetric Sensors and
Yigit C Bozkurt1, Al-Monsur Jiaul Haque1, Connor Sullivan1
1Department of Civil and Environmental Engineering, University of Massachusetts Lowell, Lowell, Massachusetts 01854, United States.
Abstract:
Lead (Pb2+) contamination in drinking water remains a critical public health concern, particularly for children, due to lead pipes and plumbing in many water systems. Conventional Pb2+ detection methods, such as ICP-MS and AAS, are costly, time-intensive, and require specialized personnel. In this study, we developed and utilized a portable voltammetric Pb2+ detection system, the E-Tongue, which features a mercury-free, gold nanostar-modified screen-printed carbon electrode, and nontoxic buffer reagents (0.1 M sodium acetate, 0.1 mM potassium ferrocyanide, pH 4.5). The E-Tongue provides Pb2+ detection within 5 min with a method detection limit of 1.6 ppb and a wide linear range of 5-200 ppb. Results demonstrated the E-Tongue's ability to detect Pb2+ above the EPA action level (10 ppb), even in high Cu2+ conditions (up to 1.3 ppm), with Pb2+ recovery of 84-105% and RSD < 10%. The E-Tongue's color-coded and quantitative feedback enables nonexperts to test tap water and share data, facilitating community-driven monitoring and intervention strategies. Additionally, spatial analysis revealed that Andover had the most alkaline and conductive tap water, while Lawrence exhibited neutral water on average. The E-Tongue empowers communities, demonstrating the potential of participatory approaches for lead detection and mitigation in water networks.
More Related Videos
12:50Continuous Instream Monitoring of Nutrients and Sediment in Agricultural Watersheds
Published on: September 26, 2017
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Voltammetric Techniques: Linear-Scan (E vs Time)