Takutoshi Inoue1, Toru Yamamoto2, Joe Iwanaga3
1Department of Anatomy, Teikyo University School of Medicine, Tokyo, JPN.
Abstract:
The modified Allen's test (MAT) is a non-invasive test for evaluating the circulation of the hand, including the superficial palmar arch (SPA). However, although there are many variations of SPA, it cannot be said that it is widely recognized in clinical practice. Herein, we report an incomplete SPA observed in the right hand of an 83-year-old male cadaver. Notably, the superficial palmar branch of the radial artery ran superficial to the abductor pollicis brevis muscle, and no median artery was identified. Six common palmar digital arteries, that is, four from the ulnar artery and two from the radial artery, were observed. This anatomical configuration lacked an anastomotic connection between the radial and ulnar arteries, suggesting insufficient collateral circulation. As a result, performing the MAT in such a case may yield a "positive" result, indicating inadequate collateral blood flow. However, in the context of an incomplete SPA, this result may reflect a true anatomical limitation rather than a pathological arterial obstruction. Therefore, clinicians must consider underlying anatomical variations when interpreting MAT results. Supplemental diagnostic tools, such as Doppler ultrasonography or pulse oximetry, may help distinguish between anatomical variants and vascular pathology. Recognizing these variations is essential for accurate circulatory assessment and safe hemodynamic monitoring during anesthesia and other clinical interventions.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Arteries of the Upper Limbs
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: