Andrés Mauricio Enríquez Popayán1, Iván Ignacio Ramírez2, Juan Felipe Zúñiga3
1Departamento de Fisioterapia en Cuidado Intensivo, GyO Medical, Yopal, Colombia; Departamento de Fisioterapia en Cuidado Intensivo, Clínica SIMALINK, Yopal, Colombia.
Introduction:
Patient-ventilator asynchrony (PVA) is frequent in intensive care. Its presence is associated with prolonged days of mechanical ventilation and may lead to increased mortality in the intensive care unit (ICU) and hospital. Little is known about the ability of Colombian intensive care professionals to identify asynchronies, and the factors associated with their correct identification are not apparent.
Aim Of The Study:
To describe the ability of Colombian intensive care professionals to identify patient-ventilator asynchronies (PVA) using waveform analysis. In addition, to define the characteristics associated with correctly detecting PVA.
Material And Methods:
We conducted a multicenter, cross-sectional, national survey-based study between January and August 2024. Colombian physiotherapists, respiratory therapists, nurses and intensive care physicians from 24 departments participated in the study. An online survey was used. They were asked to identify six different PVAs presented as videos. The videos were displayed using pressure/time and flow/time waveform of a Puritan Bennett 840 ventilator.
Results:
We recruited 900 participants, 60% female, most of whom were physiotherapists (53%). Most professionals had specialty training in critical care (42%), and 32% reported having specific PVA training. Double triggering was the most frequently identified PVA (75%). However, only 3.67% of participants recognized all six PVAs. According to multiple logistic regression analysis, working in a mixed unit (OR 2.59; 95% CI 1.19 - 5.54), caring for neonates (OR 5.19; 95% CI 1.77 - 15.20), and having specific training (OR 2.38; 95% CI 1.16 - 4.76) increases the chance of correctly recognizing all PVAs.
Conclusion:
In Colombia, a low percentage of professionals recognize all PVAs. Having specific training in this topic, working in mixed ICUs and neonatal intensive care was significantly associated with identifying all PVAs.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...