Related Experiment Video
Updated: May 23, 2025

Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
The diagnostic value of two-dimensional shear-wave elastography in identifying malignant lesions in lymph nodes: a
Jing Chen1,2,3, Yao Deng1,2,3, Jiajia Xiong1,2,3
1Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Abstract:
This study evaluates the diagnostic performance of two-dimensional shear wave elastography (2D-SWE) in differentiating between benign, metastatic lymph nodes (LNs) and lymphomas. From May 2022 to February 2023, a total of 137 patients who presented with unexplained LN enlargement were examined at the Ultrasound Medical Department of Union Hospital of Huazhong University of Science and Technology. The conventional ultrasound recorded the location, longitudinal diameter, transverse diameter, L/T ratio, blood supply mode, lymphatic hilum and 2D-SWE calculated the average elasticity (E) of LN. Histopathology was the diagnostic gold standard. A total of 124 patients with 159 superficial LNs were included (32 benign, 70 metastatic, 57 lymphoma). Malignant LNs had significantly higher E values than benign ones (49.38 ± 29.96 kPa vs. 25.00 ± 14.42 kPa, P < 0.001). When E > 25.46 kPa, the AUC, sensitivity, specificity, PPV, NPV and accuracy were 0.807, 0.787, 0.750, 0.926, 0.471 and 0.780, respectively, in identifying malignant LNs. For distinguishing benign LNs from lymphoma, the E cutoff was 25.03 kPa, with the AUC, sensitivity, specificity, PPV, NPV and accuracy of 0.727, 0.754, 0.719, 0.827, 0.622 and 0.742, respectively. To differentiate benign from metastatic LNs, an E cutoff of 36.97 kPa yielded an AUC, sensitivity, specificity, PPV, NPV and accuracy of 0.872, 0.757, 0.875, 0.930, 0.622 and 0.794, respectively. Comparing lymphoma and metastatic LNs, the E cutoff was 42.57 kPa. And the AUC, sensitivity, specificity, PPV, NPV and accuracy were 0.787, 0.700, 0.860, 0.860, 0.700 and 0.772, respectively. 2D-SWE parameter (the average elasticity) can effectively evaluate benign, metastatic LNs and lymphoma, which provides valuable information for preoperative evaluation of superficial LNs.
More Related Videos
08:18Analysis of Lymph Node Volume by Ultra-High-Frequency Ultrasound Imaging in the Braf/Pten Genetically Engineered Mouse Model of Melanoma
Published on: September 8, 2021
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014