A fault diagnosis method for inter-turn short circuit based on magnetic field distribution
1College of Information Science and Engineering, Northeastern University, Shenyang, 110819, People's Republic of China.
Abstract:
Inter-turn short circuit (ITSC) faults are among the most critical and frequent failures in power transformer windings. However, conducting a quantitative analysis of the winding insulation state based on MFL remains challenging. This paper proposes a magnetic-electrical spatial state model that links local fault currents to leakage magnetic field variations. A data-driven fault localization framework is developed by combining recursive feature elimination (RFE), Spearman correlation analysis, and support vector machine (SVM) classification. Experimental validation on a 3 kW dry-type transformer, enhanced with FEM-based signal augmentation, shows that the method achieves 97.4% fault localization accuracy under rated load using only 20 Hall-effect sensors. Under no-load conditions, the accuracy remains 92.3%, demonstrating robustness against weak excitation and electromagnetic noise. The optimized sensor layout in the winding gap enhances spatial sensitivity while minimizing hardware complexity. These results confirm the method's potential for scalable, non-intrusive insulation monitoring in practical power transformers.
More Related Videos
09:43Optimized Setup and Protocol for Magnetic Domain Imaging with In Situ Hysteresis Measurement
Published on: November 7, 2017
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Power System Three-Phase Short Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Biot-Savart Law: Problem-Solving
Consider a mobile phone battery bank as a source of steady current, which flows through the wire connected between the two. What is the magnitude of the magnetic field created by this current at a field point P?
To estimate the magnitude of the total magnetic field, we first consider a small current element of length dl, at a distance r from the field point. Now the following...