A fault diagnosis method for inter-turn short circuit based on magnetic field distribution

Bowen Wang1, Lulu Wang2

  • 1College of Information Science and Engineering, Northeastern University, Shenyang, 110819, People's Republic of China.

Scientific Reports
|May 19, 2025
PubMed

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
71
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
110
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
96
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
81
Magnetic Field of a Solenoid01:18

Magnetic Field of a Solenoid

A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field due to a solenoid is the vector sum of the magnetic fields due to its individual turns. Therefore, for an ideal solenoid, the magnetic field within the solenoid is directly proportional to the number of turns per unit length and the current. Conversely, the magnetic field outside the solenoid is zero.
Consider a solenoid with 100 turns wrapped around a cylinder of...
3.7K
Biot-Savart Law: Problem-Solving00:59

Biot-Savart Law: Problem-Solving

The magnitude and direction of a magnetic field created by a steady current can be calculated using the Biot-Savart law.
Consider a mobile phone battery bank as a source of steady current, which flows through the wire connected between the two. What is the magnitude of the magnetic field created by this current at a field point P?
To estimate the magnitude of the total magnetic field, we first consider a small current element of length dl, at a distance r from the field point. Now the following...
2.4K