Related Experiment Video
Updated: May 22, 2025

A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
Published on: April 21, 2017
Accelerometer Output and Oxygen Uptake in Adults With and Without Down Syndrome: METs vs. Percent VO2Reserve
S Agiovlasitis1, B K Ballenger2, P Choi3
1Department of Kinesiology, Mississippi State University, Starkville, USA.
Background:
The estimation of physical activity (PA) and sedentary behaviour with accelerometers is typically based on the relationship between accelerometer output and metabolic equivalents (METs)-an index of PA intensity. But for adults with Down syndrome (DS), PA intensity may be better reflected in the percent oxygen uptake reserve (%VO2Reserve), as it accounts for their lower aerobic fitness. This study examined if the relationship between accelerometer output and METs or %VO2Reserve across various PAs and sedentary behaviours differs between adults with and without DS.
Methods:
Forty-one adults with DS (age 35 ± 9 years; 18 women) and 41 adults without DS (age 24 ± 5 years; 18 women) performed 17 tasks of varying intensity. We estimated aerobic fitness with a submaximal treadmill test. We measured oxygen uptake with portable calorimetry and expressed it as METs and %VO2Reserve. Output from triaxial accelerometers on the nondominant hip and wrist was determined as Vector Magnitude (VM). We used multilevel modelling to evaluate the relationships of METs or %VO2Reserve with VM, controlling for body mass index (BMI) and age.
Results:
For the hip accelerometer, VM and the group-by-VM interaction significantly predicted METs (p < 0.001; conditional R2 = 0.82), but between-group differences were small. For the wrist accelerometer, VM and age significantly predicted METs (p < 0.035; conditional R2 = 0.76). For both the hip and the wrist accelerometer, VM, the group-by-VM interaction and BMI significantly predicted %VO2Reserve (p ≤ 0.047; conditional R2 = 0.82 and 0.74, respectively). Between-group differences in the response to VM were larger for VO2Reserve than METs models.
Conclusion:
The relationship between accelerometer output and %VO2Reserve across PAs and sedentary behaviours is different between adults with and without DS. Calibrating accelerometer output against %VO2Reserve may be preferable to METs.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...