Related Experiment Video
Updated: May 6, 2026

Determining 3D Flow Fields via Multi-camera Light Field Imaging
Published on: March 6, 2013
A retraced spiral strategy with semi-automatic deblurring for volumetric thermometry
Steven P Allen1, Sheng Chen2, Kang Yan2
1Department of Electrical and Computer Engineering, Brigham Young University, Provo, Utah, USA.
Purpose:
To develop a 3D MRI-thermometry technique for transcranial MR-guided focused ultrasound (MRgFUS).
Methods:
A stack of retraced in-out (RIO) spirals was incorporated into a 3D, RF-spoiled, gradient recalled echo (GRE) sequence with a minimized energy deblurring strategy. Bloch simulations examined isochromat precession during RIO readout under temperature profiles matching those encountered during transcranial MRgFUS and measured the resulting effects on observed peak temperatures and FWHM of the heating patterns. The sequence then monitored temperatures in a phantom undergoing insonation from an MRgFUS device. Finally, the sequence monitored temperatures, without insonation, in four patients immediately after MRgFUS thalamotomy. For comparison, temperatures were also monitored using a frequently used, 2D, Cartesian, multi-echo, spoiled GRE sequence.
Results:
The RIO sequence removed under-and over-estimation of peak temperatures produced by spiral-in and spiral-out portions, respectively, of the RIO readout. In phantoms, peak temperatures from the RIO sequence were statistically indistinguishable from those from the Cartesian sequence (p > 0.05). While, in silico, the RIO sequence accurately estimated heating FWHM (error <1 mm), in phantoms, the RIO sequence overestimated FWHM (error ˜ 1 mm, p < 0.05), when compared to the Cartesian sequence. In patients, the RIO sequence had a 40% improvement in temperature efficiency compared to the Cartesian sequence, with average temperature uncertainties of 1.32 and 1.75°C, respectively. The RIO sequence also produced residual blur artifacts at tissue interfaces.
Conclusions:
The 3D RIO strategy with deblurring monitored focal heating under transcranial MRgFUS conditions with similar accuracy and precision as an existing 2D Cartesian method.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...

