Related Experiment Video
Updated: May 23, 2025

Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
Emergency Renal Replacement Therapy with Manual Dialysis in Patients with Acute Kidney Injury: First-in-Human Case
Juan Pablo Gómez-Villarreal1, Paola Borbolla-Flores1, Ricardo Abraham Garza-Treviño2
1Nephrology Department of the Hospital Universitario "Dr. José Eleuterio González", Monterrey, Mexico.
Introduction:
Untreated severe renal disease can be fatal, and renal replacement therapy (RRT) is often essential for survival. However, access to RRT can be limited by resource constraints, particularly in emergency or austere settings. There is a critical need for portable, cost-effective, and efficient medical devices capable of delivering RRT. This case report describes the first-in-human use of the "Kirpa Kit procedure," a manual dialysis device designed to provide RRT when conventional dialysis resources are unavailable or overwhelmed.
Case Presentation:
A 37-year-old previously healthy male presented with a gunshot wound to the left leg, resulting in significant vascular injury and hemorrhagic shock requiring surgical intervention. Postoperatively, the patient remained intubated and hemodynamically unstable, developing stage 3 acute kidney injury necessitating continuous renal replacement therapy (CRRT). Due to further deterioration and the need for amputation, the patient was confined to the operating room (OR), where CRRT could not be performed. Given the patient's anuria and fluid overload, the nephrology team assessed the patient and determined he was a suitable candidate for manual dialysis using the Kirpa Kit™, with ultrafiltration (UF) as the primary objective for fluid removal. A total of 600 mL of UF was safely removed (UF rate of 600 mL/h), and the patient demonstrated both clinical and ultrasonographic improvement. Notably, portal vein pulsatility decreased from 38% to 31% following the procedure, indicating a reduction in fluid overload. The patient's vital signs remained stable throughout.
Conclusion:
The Kirpa Kit procedure was successfully and safely used to manage fluid overload in a critically ill patient, demonstrating its potential as an emergency dialysis device for bridging patients with renal emergencies to standard RRT in resource-limited environments. Further studies are needed to evaluate the device's broader applications and limitations.
Related Concept Videos
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Kidney Structure
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...

