Background:
Glomerular filtration rate (GFR) is recognized as the most reliable indicator of renal function and is usually estimated based on the serum creatinine equations. However, the reliability of these equations in specific regions needs to be properly quantified. We evaluated the applicability of the abbreviated MDRD equation (aGFR), the modified abbreviated MDRD equation (maGFR), the CKD-EPI creatinine equation (C-GFRcr), the CKD-EPI creatinine-cystatin C equation (C-GFRcr-cys), the EKFC creatinine equation (E-GFRcr), and the EKFC creatinine-cystatin C equation (E-GFRcr-cys) to chronic kidney disease (CKD) patients in Chongqing, China.
Methods:
A total of 234 adult patients with CKD were selected for the study. Their sex, age, and etiology of CKD were recorded, and serum creatinine and cystatin C were measured and traceable to primary reference materials. The technetium 99 m-labeled diethylenetriamine pentaacetate (99mTc-DTPA) renal scintigraphy was used as the reference method for GFR measurement. Six GFR estimation equations were analyzed in the overall analysis and across various stages of CKD to evaluate differences, absolute differences, bias, precision, and accuracy.
Results:
In the validation dataset, the differences for maGFR were smaller compared to other equations, while those for C-GFRcr-cys and E-GFRcr-cys were larger. The bias for C-GFRcr-cys and E-GFRcr-cys was significantly higher than that of the other equations, although all six equations exhibited similar levels of precision. In CKD stages 1 through 3, the accuracy of C-GFRcr-cys and E-GFRcr-cys was significantly lower when compared to the other equations. Conversely, in CKD stages 4 and 5, maGFR and E-GFRcr-cys demonstrated significantly greater accuracy than the other equations. In CKD stage 1, maGFR misclassified only 5.21 % of patients, whereas C-GFRcr-cys and E-GFRcr-cys had significantly higher misclassification rates of 66.67 % and 68.75 %, respectively, compared to the other equations.
Conclusions:
Overall, maGFR performed better than other equations and can be used as a confirmatory test in CKD patients in Chongqing, China.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...