Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
UTransBPNet for cuffless and calibration-free blood pressure estimation under dynamic conditions
Yali Zheng1, Hongda Huang2, Jiasheng Gao2
1Department of Biomedical Engineering, College of Health Science and Environmental Engineering, ShenzhenTechnology University, Shenzhen, China. zhengyali@sztu.edu.cn.
Abstract:
Accurate cuffless blood pressure (BP) estimation remains challenging, particularly under dynamic conditions with significant intra-individual BP variations. This study introduces UTransBPNet, a novel, calibration-free model for cuffless BP estimation. It integrates a squeeze-and-excitation-enhanced Unet architecture for short-range feature extraction with a transformer and cross attention module to capture long-range dependencies from high-resolution, multi-channel physiological signals, further refined through an optimized fine-tuning scheme. Comprehensive validations were conducted across multiple dynamic datasets-Dataset_Drink, Dataset_Exercise, and Dataset_MIMIC-in both scenario-specific and cross-scenario settings. Results demonstrate that UTransBPNet outperformed existing models in tracking BP variations under dynamic conditions, achieving individual Pearson's correlation coefficients of 0.61 ± 0.17 and 0.62 ± 0.13 for systolic BP (SBP) and diastolic BP (DBP) in Dataset_Drink, 0.82 ± 0.11 and 0.72 ± 0.18 in Dataset_Exercise, and low mean absolute differences (MADs) of 4.38 and 2.25 mmHg in Dataset_MIMIC. The analysis also highlights the impact of dataset characteristics on model performance, such as distribution shift, distribution imbalance and individual BP variability, highlighting the need for well-curated data to ensure generalizability. This study advances the development of robust, cuffless BP estimation models for real-world applications.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)