Related Experiment Video
Updated: May 23, 2025

Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
Published on: April 19, 2024
How to personalise ventilation of infants with congenital diaphragmatic hernia? A simulation study
Barbara Stankiewicz1, Magdalena Mierzewska-Schmidt2, Krzysztof J Pałko3
1Department of Modeling and Supporting Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland. bstankiewicz@ibib.waw.pl.
Background:
We aim to develop a non-invasive, bed-side method for supporting personalised ventilation of neonates with congenital diaphragmatic hernia (CDH). Currently, there are no CDH severity measures to do it. As ventilation inhomogeneity (VI) resulting from lung hypoplasia is highly variable in CDH patients, mechanical ventilation is a real challenge and the risk of lung injury is high.
Methods:
We conducted 250 simulations of conventional ventilation of CDH cases using the infant hybrid (numerical-physical) respiratory simulator and a ventilator. Utilising simulation results, we searched for a regression model describing patient ventilation parameters as a function of the respiratory system parameters, ventilator settings and two new CDH severity measures: VI-degree defined as a ratio of time constants ratio of the contralateral and ipsilateral lung (T1/T2) and chest-wall-to-lung compliance ratio (CW/CL). The regression model aimed to find the T1/T2 and CW/CL values for real CDH cases and estimate optimal, matched to VI-degree, peak inspiratory and mean airway pressure (PIP, MAP).
Results:
The developed regression models (R2 = 0.78 ÷ 0.98; P < 0.001) enabled to find clinically hard-to-measure values of T1/T2 and CW/CL ratios for three patients, respectively: 9 and 6.52 (P1), 3.5 and 4.96 (P2), and 4 and 5.02 (P3). The T1/T2 and CW/CL correlated with defect size (gamma coefficient: 1; P < 0.05), duration of mechanical ventilation and hospitalization (Spearmen's coefficient: 0.99; P < 0.01). The clinical and estimated PIP and MAP didn't differ statistically.
Conclusion:
The T1/T2 and CW/CL indices can help to personalize CDH infants' ventilation and might be used for prognostication.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

