Related Experiment Video
Updated: Jul 22, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro
Abstract:
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia implants. Monolithic incisor and molar zirconia crowns (n = 8 per group) were cemented on either PEKK or zirconia screw-retained abutments on zirconia implants. Molar and incisor crowns were also cemented on screw-retained titanium abutments on titanium implants as control. All specimens were subjected to combined mechanical loading (1.2 × 106 cycles of 50 N, f = 1 Hz) and thermal cycling (2 × 3000 × 5°C/55°C cycles of 2 minutes). Complications, such as loosening of the crowns and fractures, were observed. The surviving specimens were subjected to a fracture test. Descriptive statistics were applied to complications, survival times, and fracture forces. The occurrence of complications depended significantly on location (anterior or posterior) and material (P < .0001). While the incisor test groups presented higher failure rates for both PEKK and zirconia abutments, the survival rates of the molar-shaped crowns of both test groups were comparable with those of the titanium control group. This highly significant interaction is caused by a substantial difference in location for PEKK and zirconia (P < .05). The titanium control group showed uniform performance independent of the simulated site. PEKK abutments showed high survival rates for in vitro simulated molar sites. Screw-retained zirconia abutments have shown higher complication rates, especially in simulated anterior sites. Neither zirconia nor PEKK abutments are recommended in clinical application for anterior indication.
Related Concept Videos
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Fiber Reinforced Concrete

