Related Experiment Video
Updated: Jul 12, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
DoseCV: Dose coefficient calculation from MCNP simulations with MRCP phantoms
Válter J Coutinho1, Willian K S Nakano2, Ana P Perini1
1Programa de Pós-Graduação em Engenharia Biomédica, Universidade Federal de Uberlândia, Av. João Naves de Ávila, 2121, Uberlândia, 38408-144, MG, Brazil; Instituto de Física, Universidade Federal de Uberlândia, Av. João Naves de Ávila, 2121, Uberlândia, 38408-144, MG, Brazil.
Abstract:
The level of detail of computer phantoms has increased over the years, thereby reproducing the human body more reliably. The Mesh-type Reference Computational Phantoms are an evolution of those from ICRP Publication 110, and are now available in polygon meshes. Analyzing MCNP simulation results using these phantoms can be time consuming and error prone due to the large amount of data generated by the program. This article then proposes the creation of a software called DoseCV to help process the output data from the MCNP simulations. The POLY2TET tool was used to tetrahedralize the phantoms, and DoseCV was used to process the output data. The results obtained were validated by comparing them with ICRP Publication 116 data. In general, considering the DCs found for the six simulated energies, an error of less than 5% was obtained for 88.9% of the target tissues of MRCP-AF and 76.7% of MRCP-AM. In its actual version, DoseCV can convert tally data into a dose coefficient (DC), equivalent dose conversion coefficient (CC[HT]), effective dose conversion coefficient (CC[E]), equivalent dose (HT), and effective dose (E). The combined use of POLY2TET and DoseCV proved to be an effective tool for processing data from the MCNP simulations.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Dosage Regimens: Partial Pharmacokinetic Parameters
Pharmacodynamic Models: Additive and Proportional Drug Effect Model
Pharmacokinetic–Pharmacodynamic Relationship: Dose to Pharmacological Effect