Related Experiment Video
Updated: May 17, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
SPE-LC-MS/MS optimisation using response surface methodology for quantification of pharmaceuticals, pesticides and
Ana M Gorito1, Beatriz R Mota1, Adrián M T Silva1
1LSRE-LCM - Laboratory of Separation and Reaction Engineering - Laboratory of Catalysis and Materials, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal.
Abstract:
The environmental concern about micropollutants (MPs) in aquatic environments has grown significantly in recent decades due to their widespread occurrence and potential risks to ecosystems and human health. Monitoring of MPs is crucial for understanding the status of aquatics systems, supporting risk assessments, developing elimination strategies, and informing regulatory decision-makers. However, due to the very low concentrations of MPs (usually ranging between ng L-1 and μg L-1 levels), their quantification requires highly sensitive and precise analytical methods. Solid phase extraction (SPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has emerged as the preferred technique for analysing MPs in water. Nonetheless, developing multi-residue analytical methods remains challenging due to the diverse nature of these compounds. Specifically, in SPE, various parameters can significantly influence the efficiency of the process and, therefore, optimisation strategies are needed to reduce time, costs and environmental impacts. This study focuses on using design of experiments (DoE) with response surface methodology (RSM) aiming to optimise, for the first time, an SPE-LC-MS/MS method for the analysis of pharmaceuticals, pesticides and organic UV filters included in the European Union (EU) water protection guidelines. The optimised SPE conditions (sample pH of 3-4, sample volume of 375 mL, and 3.5 mL of ethanol (EtOH) as the eluent) resulted in a MPs average extraction efficiency (EE) of 65 %, matrix effect (ME) of 8 %, and an absolute recovery (AR) of 73 %. Accordingly, the SPE-LC-MS/MS method was successfully validated for routinely monitoring 32 target MPs in surface water (SW) matrices.
More Related Videos
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019