Related Experiment Video
Updated: Sep 20, 2025

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Noninvasive Pressure-Volume Analysis by Three-Dimensional Echocardiography: A Novel Powerful Method for Evaluating
Lars-Egil R Hammersboen1, Espen Boe2, Jürgen Duchenne3
1Institute for Surgical Research, Oslo University Hospital, Rikshospitalet, Oslo, Norway; Division of Cardiovascular and Pulmonary Diseases, Cardiology Department, Oslo University Hospital, Rikshospitalet, Oslo, Norway; Faculty of Clinical Medicine, University of Oslo, Oslo, Norway.
Background:
Pressure-volume (PV) analysis is the gold standard for evaluating left ventricular (LV) function but is rarely used clinically due to its invasiveness. We validated a noninvasive method for PV analysis by three-dimensional (3D) echocardiography against invasive reference measurements and a novel index of LV efficiency against LV efficiency derived from metabolism by positron emission tomography-computed tomography (PET-CT).
Methods:
In 22 canines, LV volume was measured invasively using piezoelectric crystals and LV pressure by micromanometer. Echocardiography and peak pressure were used to obtain 3D LV volume traces and LV pressure trace estimates. Stroke work, single-beat contractility indices, arterial elastance, and an index of LV efficiency were derived from echocardiography and compared with their invasively measured counterparts at baseline and different interventions. In 12 sheep, the LV efficiency index was compared with efficiency calculated as stroke work divided by total LV glucose metabolism from PET-CT. The sheep underwent 8 weeks of rapid dyssynchronous pacing to induce heart failure (HF). Recordings were performed during synchronous and dyssynchronous electrical activation, at baseline, and after 8 weeks of pacing-induced HF.
Results:
In canines, there was a very good correlation and agreement between noninvasive and invasive measurements of LV stroke work (r = 0.98, P < .0001; difference 237 ± 212 mm Hg × mL, mean ± SD). The noninvasive and invasive efficiency indices also showed very good agreement (r = 0.95, P < .0001; difference 0.4% ± 3.4%). The changes in LV function by the different interventions resulted in similar changes in the noninvasive and invasive PV indices (all P < .001). In sheep, the efficiency index showed similar decline compared to efficiency by PET-CT after induction of HF and after switching from synchronous to dyssynchronous electrical activation (r = 0.67, P < .001 for all interventions).
Conclusions:
Noninvasive PV analysis by three-dimensional echocardiography is feasible and accurate, making PV loop parameters for evaluating LV function accessible for clinical use. Further studies should explore the clinical utility of this method.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiac Catheterization III: Left Heart Catheterization