Related Experiment Video
Updated: Jul 13, 2026

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
FLASH Stereotactic Body Radiation Therapy for Spine Tumors Using a Single-Energy Proton Pristine Bragg Peak Delivery
Balaji Selvaraj1, Xingyi Zhao1, Haibo Lin1,2
1New York Proton Center, New York, New York.
Purpose:
To investigate the dosimetric performance and dose rate of Bragg peak FLASH (BP-FLASH) for spinal cord stereotactic body radiation therapy (SBRT).
Methods And Materials:
Ten consecutive patients with spinal tumors treated with conventional intensity modulated proton therapy (CONV-IMPT) SBRT (40 Gy in 5 fractions) were selected for this study. These patients were reoptimized using an in-house FLASH algorithm and a single-energy Bragg peak approach. The dose distributions and dose metrics for target coverage and critical organs-at-risk (OARs) were compared. BP-FLASH plans dose rates were calculated using an average-dose-rate. The FLASH ratios (V40Gy/s) were assessed with dose thresholds at 0.2, 2, and 5 Gy. The doses and dose rates for the 10 patients were averaged, and a t test was performed comparing CONV-IMPT and BP-FLASH.
Results:
Dosimetric analysis revealed that the BP-FLASH plans deliver a similar dose as CONV-IMPT plans to critical OARs. However, in BP-FLASH, the clinical target volume received a higher maximum dose than CONV-IMPT (115.1% versus 108.9%, P = .001). No notable differences were observed in the maximum doses to the spinal cord (P = .122) or esophagus (P = .327). FLASH dose rates for all the OARs exceeded 80% with 2 Gy dose threshold. When increased to 5 Gy, V40Gy/s increased to >95% for composite plan doses.
Conclusions:
BP-FLASH SBRT is a promising treatment for challenging spinal cord cancers, which achieved ultra-high-dose rates for FLASH effect and maintained the same dosimetry quality as the CONV-IMPT plans.