Related Experiment Video
Updated: Sep 20, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Does capnography improve safety in moderate-deep sedation for gastrointestinal endoscopic procedures provided by
Isabel Valbuena1, Azahara Sancho2, Estíbaliz Alsina2,3
1Department of Anaesthesiology and Intensive Care Medicine, Hospital Universitario La Paz, Madrid, Spain. isa_valbuena_gomez@hotmail.com.
Abstract:
This study aimed to determine whether the use of capnography reduces the incidence of respiratory and cardiovascular adverse events during procedural sedation and analgesia (PSA) for gastrointestinal endoscopic procedures (GEP) provided by experienced anaesthesiologists. A prospective cohort study was conducted, including patients undergoing GEP under PSA. Patients were divided in two groups: Group A (pulse oximetry) and Group B (capnography with Capnostream™ monitor plus pulse oximetry). Interventions undertaken to resolve hypoxaemia, airway obstruction, or apnoea were recorded. Age, comorbidities, ASA Classification, sedative drugs, respiratory and cardiovascular adverse events, recovery Aldrete Scale value, and patient satisfaction were also recorded. Both parametric and non-parametric tests were applied. A total of 1,146 patients were included: Group A, n = 538, and Group B, n = 608. Diagnostic colonoscopy was the most frecuent procedure (49.7%), followed by diagnostic gastroscopy (22.5%) and therapeutic colonoscopy (22.2%). Apnoea < 60 s was detected only in patients monitored with capnography (35.4% vs. 0%, p < 0.000). The use of capnography significantly reduced the incidence of moderate hypoxaemia (3% vs. 6.5%, p = 0.004). Severe hypoxaemia was significantly reduced with capnography only in patients with cardio-respiratory comorbidities (2.2% vs. 4.4%, p = 0.032). The capnography group showed a lower incidence of cardiovascular events. Respiratory adverse events, such as desaturation and airway obstruction, increased with age and ASA classification, as did the need for airway maneuvers. Prolonged apnoea and intubation were rare in both groups. Mandibular traction manoeuvres were significantly more frequent in Group B (9.9% vs. 3%, p < 0.000), reducing the need for other interventions. Patient satisfaction at discharge was higher when capnography was used (p < 0,000). Moderate-deep sedation for GEP performed by experienced anaesthesiologists, combined with capnography, enhances safety, with extremely rare major complications. Capnography monitoring allowed the timely identification and resolution of apnoea and airway obstruction, avoiding severe desaturation and cardiovascular adverse events.
More Related Videos
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures II: Colonoscopy
Stages of General Anesthesia