Optimal Electrode Configuration for Masseter Vestibular-Evoked Myogenic Potential: A Comparison Between Zygomatic and
Aishwarya Nagarajan1, Sujeet Kumar Sinha2
1*Department of Audiology, All India Institute of Speech and Hearing, Mysore, India.
None:
Background: The masseter vestibular-evoked myogenic potential (mVEMP) is a short-latency electromyographic potential that assesses the integrity of the vestibule-masseteric reflex pathway. Due to limited normative studies, there is no optimal mVEMP protocol to be implemented clinically. Apart from the conventional electrode configuration, a naïve montage referred to as the forehead reference has been used in recent studies. Purpose: This study compared latency and amplitude parameters of mVEMP between the zygomatic and forehead electrode configurations to address the optimal electrode montage to elicit mVEMP. Research Design: Cross-sectional research study. Study Sample: Thirty healthy participants (mean age: 23.3 years; 14 males and 16 females). Data Collection and Analysis: Participants underwent mVEMP testing under two-electrode montage conditions (zygomatic and forehead reference electrode montages). Results: Statistically significant increases in P1 latency, decrease in N1 latency, reduction of P1-N1 interpeak interval, enlargement of both unrectified and electromyography-rectified amplitudes, and lower interaural amplitude asymmetry ratio were observed for the forehead electrode montage compared to the conventional zygomatic montage. Conclusions: mVEMP response waveforms obtained using forehead reference electrode montage are superior to the zygomatic montage. Hence, the forehead montage is suggested for further research on mVEMP.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...