Introducing the Concept of Error Vectors to Improve Source Localization Results of Epileptic Discharges
Kanjana Unnwongse1, Carsten H Wolters2,3, Tim Wehner1
1Ruhr-Epileptology, Department of Neurology, University Hospital Knappschaftskrankenhaus, Ruhr-University Bochum, Bochum, Germany.
Purpose:
To improve EEG source localization results of interictal epileptic discharges (IED) by applying postprocessing step to electrical source imaging (ESI).
Methods:
Localization error of ESI was evaluated in comparison to known sources of stimulation potentials (ESP) by recording simultaneous stereo-EEG/scalp EEG. Error vectors were defined as the offset of the ESI-dipole of ESP to the stereo-EEG contacts used for stimulation. The inverted error vector was applied to the ESI-dipole of IED (IED-dipole).
Results:
Seven IED clusters were evaluated. Corrected IED-dipoles were located closer to IED-onset contacts on stereo-EEG than uncorrected IED-dipoles ( median [ IQR ]: 7.8 [2.5] versus 18.7 [10.7] mm, P = 0.02). Anatomically, for high skull conductivities, all corrected IED-dipoles were located in cortical structures or adjacent to epileptogenic lesion, whereas uncorrected IED-dipoles were located in white matter or CSF ( P = 0.02). Physiologically, cortical extent of IED generators estimated from corrected IED-dipoles was 16.5 cm 2 ( IQR = 10.4 cm 2 ) and 7.4 cm 2 (range 5.8-9.2 cm 2 ) in the group of anterior temporal IED and prefrontal IED, respectively; the former was concordant with the extent estimated by subdural electrodes. In addition, the relationship of stereo-EEG IED amplitude (a) drop with increasing distance (d) from corrected IED-dipole could be modeled as a negative power equation a(d)∝1/d b ( R2 = 0.87, P < 0.01), with b ranging from 0.79 to 2.3, median: 1.57, consistent with a simulation model of the sensitivity of intracerebral electrode.
Conclusions:
Application of inverted error vector reduces localization error and shifts IED-dipole to an anatomically and physiologically plausible location.
Related Concept Videos
Discharge Summary Forms
Here's a detailed look at the key components and guidelines for preparing a discharge summary:
Self-Concept
Infancy and Emerging Recognition
During infancy, self-concept is virtually nonexistent. Babies do not distinguish themselves as separate entities and often mistake their...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
RC Circuits: Discharging A Capacitor
Random Error