Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Late-onset medication-related osteonecrosis of the jaw 11 years after IV bisphosphonates following implant placement.

Clinical advances in periodonticsĀ·2026
Same author

CAD-CAM ceramic material options for discolored teeth.

The Journal of prosthetic dentistryĀ·2026
Same author

Assessment of 3D facial scan integration in 3D digital workflows using radiographic markers and the iterative closest point algorithm.

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2026
Same author

Evaluating AI Chatbot Performance Against Prosthodontic Residents on the National Prosthodontic Resident Examination (NPRE) from 2011 to 2023.

The International journal of prosthodonticsĀ·2025
Same author

The Impact of Age and Gender on Patient Grievances in a Dental Academic Setting: A 6-Year Analysis.

European journal of dental education : official journal of the Association for Dental Education in EuropeĀ·2025
Same author

Effect of different implant abutment materials on optical properties of translucent monolithic zirconia crowns.

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2025
Same journal

Complete denture soft liners improve bite force, mastication, and life quality: A systematic review and meta-analysis.

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2026
Same journal

Impact of prosthetic abutment design on peri-implant clinical and esthetic outcomes: A systematic review and meta-analysis of randomized controlled trials.

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2026
Same journal

Influence of degree of conversion on the cytotoxicity of 3D-printed denture base resins. A scoping review.

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2026
Same journal

Effect of fabrication techniques on accuracy of maxillary denture bases in anatomically challenging scenarios: An experimental in vitro study.

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2026
Same journal

Response to the letter to the editor "Clinical and radiographic assessment of effect of platelet rich fibrinĀ on dental implant osseointegration - A split mouth randomized clinical trial".

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2026
Same journal

Influence of X-ray beam angulation on the radiographic detection of implant-abutment interface misfits: A quantitative in vitro analysis.

Journal of prosthodontics : official journal of the American College of ProsthodontistsĀ·2026
See all related articles

Related Experiment Video

Updated: Sep 20, 2025

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
07:32

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment

Published on: February 23, 2024

1.3K

Semi-adjustable digital articulator programming using eccentric interocclusal scans.

Hongseok An1, Despoina Bompolaki1

  • 1Restorative Dentistry Department, Oregon Health & Science University, Portland, Oregon, USA.

Journal of Prosthodontics : Official Journal of the American College of Prosthodontists
|May 30, 2025
PubMed
Summary
This summary is machine-generated.

This study introduces a digital articulator programming technique using eccentric interocclusal records. This method simplifies determining condylar inclinations and Bennett angles with just an intraoral scanner.

Keywords:
articulator programmingdigital articulatordigital dentistryeccentric recordsocclusion

More Related Videos

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
07:42

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material

Published on: December 20, 2024

469
Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
09:10

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures

Published on: August 5, 2021

1.9K

Related Experiment Videos

Last Updated: Sep 20, 2025

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
07:32

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment

Published on: February 23, 2024

1.3K
Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
07:42

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material

Published on: December 20, 2024

469
Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
09:10

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures

Published on: August 5, 2021

1.9K

Area of Science:

  • Dental Technology
  • Digital Dentistry
  • Prosthodontics

Background:

  • Traditional semi-adjustable articulators require complex programming.
  • Digital workflows offer potential for increased efficiency and accuracy in prosthodontics.

Purpose of the Study:

  • To describe a novel semi-adjustable digital articulator programming technique.
  • To utilize digital eccentric interocclusal records for precise articulator calibration.

Main Methods:

  • Placing temporary markers on mandibular canines and first molars.
  • Performing intraoral scans in protrusive and laterotrusive positions.
  • Determining sagittal condylar inclinations and Bennett angles from scan data.

Main Results:

  • Successful programming of a semi-adjustable digital articulator was achieved.
  • Sagittal condylar inclinations and Bennett angles were accurately determined.
  • The technique requires only an intraoral scanner, eliminating the need for additional specialized devices.

Conclusions:

  • This digital technique offers a simplified and efficient method for semi-adjustable digital articulator programming.
  • The use of digital eccentric interocclusal records enhances accuracy in determining key articulator parameters.
  • This approach integrates seamlessly into digital dental workflows.