Related Experiment Video
Updated: Mar 31, 2026

An Open-Source Normothermic Perfusion System Designed for Research Scientists
Published on: July 18, 2025
Hemolysis in a Novel Centrifugal Blood Pump With Low Priming Volume: In Vitro Comparative Study Using Human Blood and
Extracorporeal circulation (ECC) procedures, including extracorporeal membrane oxygenation (ECMO), provide essential support for critically ill patients, but complications such as hemolysis and thromboembolic events remain significant concerns. This study evaluates the hemocompatibility of the CBM LifeMotion centrifugal ECMO pump, designed with a low priming volume and shrouded impeller, comparing its performance to three commercially available pumps (Maquet, Sorin, and Novalung). Human blood was used in a simulated ECC model, following American Society for Testing and Materials (ASTM) testing protocols, to evaluate hemolysis and white blood cell damage. The CBM pump demonstrated hemolysis levels similar to the Maquet and Sorin pumps, all of which exhibited low hemolysis compared to the Novalung pump, which showed the highest hemolysis. A numerical analysis further assessed the CBM pump's performance under low-flow conditions, revealing reduced fluid shear stress due to the lower rotor speed, whereas the blood's exposure time to this shear stress increased. Despite these differences, the overall hemolytic potential under low-flow conditions was comparable to ASTM conditions. These results suggest that the CBM LifeMotion pump, with its reduced priming volume and favorable hemocompatibility, shows promise for ECMO applications. Further clinical research is required to validate these findings in real-world settings.
Extracorporeal circulation (ECC) procedures, including extracorporeal membrane oxygenation (ECMO), provide essential support for critically ill patients, but complications such as hemolysis and thromboembolic events remain significant concerns. This study evaluates the hemocompatibility of the CBM LifeMotion centrifugal ECMO pump, designed with a low priming volume and shrouded impeller, comparing its performance to three commercially available pumps (Maquet, Sorin, and Novalung). Human blood was used in a simulated ECC model, following American Society for Testing and Materials (ASTM) testing protocols, to evaluate hemolysis and white blood cell damage. The CBM pump demonstrated hemolysis levels similar to the Maquet and Sorin pumps, all of which exhibited low hemolysis compared to the Novalung pump, which showed the highest hemolysis. A numerical analysis further assessed the CBM pump's performance under low-flow conditions, revealing reduced fluid shear stress due to the lower rotor speed, whereas the blood's exposure time to this shear stress increased. Despite these differences, the overall hemolytic potential under low-flow conditions was comparable to ASTM conditions. These results suggest that the CBM LifeMotion pump, with its reduced priming volume and favorable hemocompatibility, shows promise for ECMO applications. Further clinical research is required to validate these findings in real-world settings.
More Related Videos
09:09Preparation of Primary Acute Lymphoblastic Leukemia Cells in Different Cell Cycle Phases by Centrifugal Elutriation
Published on: November 10, 2017
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
Related Concept Videos
Centrifugation
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
High-Performance Liquid Chromatography: Elution Process
Hemodialysis II: Procedure and Complications