A dimensionless approach to minimizing energy consumption in single-pass reverse osmosis desalination systems
Muhammad H Elbassoussi1, Omar G Kaoud1, Syed M Zubair2
1Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals (KFUPM), Dhahran, Saudi Arabia.
None:
This study presents a dimensionless approach to optimizing energy efficiency in single-pass multi-membrane reverse osmosis (RO) desalination. Two new dimensionless performance indices-the Recovery Ratio Index (RRI) and the Permeate Salinity Index (PSI)-were introduced to ensure feasible system recovery (0.5 ≤ RRI ≤ 1) and acceptable permeate salinity (PSI ≤ 1). A sensitivity analysis identified the dimensionless membrane parameter (Sa*) as the most influential factor affecting specific energy consumption, leading to its optimization under uniform and non-uniform distributions. For non-uniform cases, descending (higher Sa* in early membranes) and ascending (higher Sa* in later membranes) profiles were explored. The results showed that descending profiles maximize early-stage water recovery and improve efficiency for low-salinity feeds (≤ 10,000 ppm), while ascending profiles mitigate osmotic pressure buildup and enhance performance in high-salinity feeds (≥ 40,000 ppm). System size also influences the optimal strategy, with descending profiles being more effective in small systems and ascending or balanced distributions preferred in larger, multi-membrane setups. These findings provide practical design guidelines for tailoring single-pass RO configurations to feed salinity and system size.
More Related Videos
09:39Proof-of-Concept for Gas-Entrapping Membranes Derived from Water-Loving SiO2/Si/SiO2 Wafers for Green Desalination
Published on: March 1, 2020
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Related Concept Videos
Osmosis and Osmotic Pressure of Solutions
Application of the Energy Equation
Energy Considerations in Open Channel Flow
Osmosis
Water, like other substances, moves from a high concentration of...
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Fast Decoupled and DC Powerflow